AAPM CT Performance Phantom
|
| The AAPM CT Performance Phantom offers the user a single test object that measures ten distinct CT performance parameters. The phantom design is based on the guidelines presented in Report #1 of the American Association of Physicists in Medicine Task Force on CT Scanner Phantoms. |
|
|
| |
 |
CT Dose Phantom
|
| The CT Dose Phantom is manufactured to comply with the Food and Drug Administration's performance standard for diagnostic x-ray systems, which includes Computed Tomography Systems (21CFR 1020.33). |
|
|
| |
 |
ACR CT Accreditation Phantom
|
|
The ACR CT Accreditation Phantom can be used for initial QA assessment and routine monthly QA testing to help ensure that patients are receiving the lowest possible CT dose. Solid Water ® construction makes for a convenient, physically stable test device that provides reproducible results over time.
|
|
|
| |
 |
PET-CT Phantom
|
|
The PET-CT Phantom includes internal structures (three rods and six spheres) which, when imaged with both modalities, can demonstrate how accurately the two image sets are aligned.
|
|
|
| |
 |
Head/Body CT Phantom 461A
|
|
The Head/Body CT Phantom 461A provides a set
of tools for evaluating CT image quality. The main modules are constructed of Solid Water®. This permits testing without the difficulties of filling phantoms with water.
|
|
|
| |
 |
Electron Density CT Phantom EDP-62
|
|
The Electron Density CT Phantom EDP-62 can be configured to simulate the head or abdomen. Tissue-equivalent plugs made of various tissue- and water-simulating materials can be positioned at 17 different locations within the scan field.
|
|
|
| |
 |
Electron Density CT Phantom 467
|
|
The Electron Density CT Phantom 467 can be used to calibrate the CT unit by establishing the relationship between the electron density of various tissues and their corresponding CT number. This data can then be transferred to the computerized treatment planning system for more accurate corrections for tissue inhomogeneities.
|
|
|
| |
 |
Mini CT QC Phantom
|
|
The Mini CT QC Phantom is a highly versatile phantom designed for routine monitoring of the consistency of all the major parameters of computed tomography (CT) image quality and radiation dose.
|
|
|
| |
 |
CT Spiral Phantom
|
|
The CT Spiral Phantom is a supplemental phantom to the CT Performance Phantom, described in a report by the AAPM task force on CT scanner phantoms. Scanner evaluation is more realistic; what you scan, is what you see.
|
|
|
| |
 |
CT Dose Phantom Kit for Adult/Pediatric Head and Body
|
|
When performing dose profile measurements, the CT Dose Phantom Kit allow the user to collect information for the maximum, minimum and mid-range value of the nominal tomographic section thickness.
|
|
|
| |
 |
Catphan™CT Phantom
|
|
Call JRT Associates for additional information.
|
|
|
| |
 |
Spiral/Helical CT Lesion Detectability Phantom
|
| The Spiral/Helical CT Phantom is designed to test scanning protocols to verify that small low contrast lesions will be detected. The phantom permits complete testing of low contrast lesion detection when scan parameters are varied. |
|
|
| |
 |
Tissue Equivalent Abdominal CT Dose
|
| The Tissue Equivalent CT Dose Phantoms are designed to more accurately simulate the range of patient sizes from small infants to large adult patients rendering more accurate and reliable CT dose data. |
|
|
| |
 |
Interventional Triple-Modality 3D Abdominal Phantom
|
|
The Interventional Triple-Modality 3D Abdominal Phantom is made from proprietary materials which accurately mimic human tissues under magnetic resonance imaging (MRI), ultrasound, and computed tomography (CT). It is designed for image-guided interventional procedures.
|
|
|
| |
 |
CT Simulator For Bone Mineral Analysis
|
| The CT Simulator For Bone Mineral Analysis takes into account all known variability factors that can adversely affect the use of CT for bone densitometry. This anthropomorphic phantom design minimizes beam hardening effects and variances associated with scan field position. |
|
|
| |
|